4.2.2 Number of configurable inputs and outputs on the

SPC200-COM-IBS

The SPC200 communicates with the INTERBUS mo-
dule/master via internal I/O address ranges of field bus
module SPC200-COM-IBS.

PLEASE NOTE
– Field bus module SPC200-COM-IBS occupies

different inputs and outputs, depending
on the operating mode of the SPC200 and
on the I/O configuration set with WinPISA.

The Ident-code is always 3

D

/ 03

H

.

The table below gives a summary of the control signals
in the I/O address range of the field bus module. The
exact position of the control signals can be found in the
tables in Chapter 4.1.1.

Field bus module type SPC200-COM-IBS

Operating
mode

Function of the inputs/outputs

Process data
channel

Start/stop

I10.0 - I10.15

*)

I11.0 - I13.15

*)

Control signals and freely
programmable inputs
(optional) for freely
programmable inputs

16 bits

(optional)
32, 48 or 64 bits

Q10.0...Q10.15

*)

Q11.0 - Q13.15

*)

Control signals and freely
programmable outputs
(optional) for freely
programmable outputs

Record select

I10.0 - I10.15

*)

I11.0 - I11.15

*)

Control signals
Record numbers

32 bits

Q10.0 - Q10.15

*)

Q11.0 - Q11.15

*)

Control signals
reserved/unused

**)

*)

Designation scheme/address specifications as seen by the SPC200

**)

The higher number (inputs/outputs) is decisive for configuration of the process data.

4. Commissioning

SPC200-COM-IBS 0503a