4.2.2 Number of configurable inputs and outputs on the
SPC200-COM-IBS
The SPC200 communicates with the INTERBUS mo-
dule/master via internal I/O address ranges of field bus
module SPC200-COM-IBS.
PLEASE NOTE
– Field bus module SPC200-COM-IBS occupies
different inputs and outputs, depending
on the operating mode of the SPC200 and
on the I/O configuration set with WinPISA.
– The Ident-code is always 3
D
/ 03
H
.
The table below gives a summary of the control signals
in the I/O address range of the field bus module. The
exact position of the control signals can be found in the
tables in Chapter 4.1.1.
Field bus module type SPC200-COM-IBS
Operating
mode
Function of the inputs/outputs
Process data
channel
Start/stop
I10.0 - I10.15
*)
I11.0 - I13.15
*)
Control signals and freely
programmable inputs
(optional) for freely
programmable inputs
16 bits
(optional)
32, 48 or 64 bits
Q10.0...Q10.15
*)
Q11.0 - Q13.15
*)
Control signals and freely
programmable outputs
(optional) for freely
programmable outputs
Record select
I10.0 - I10.15
*)
I11.0 - I11.15
*)
Control signals
Record numbers
32 bits
Q10.0 - Q10.15
*)
Q11.0 - Q11.15
*)
Control signals
reserved/unused
**)
*)
Designation scheme/address specifications as seen by the SPC200
**)
The higher number (inputs/outputs) is decisive for configuration of the process data.
4. Commissioning
SPC200-COM-IBS 0503a