3.1 General instructions

WARNING
Before undertaking installation and/or maintenance
work, switch off the following in the sequence
specified here:
1. the compressed air supply
2. – the load voltage supply for field devices and

proportional directional control valves
(plug X2, pin 1)

– the load voltage supply for the outputs

(plug X6/X8, pin 8)

– if applicable, the load voltage supply for the

axis interface string

– the operating voltage supply for internal

electronics of the SPC200 and field devices
(plug X2, pin 2).

You thereby avoid:

– undesired movements of the connected actuators

– uncontrolled movements of loose tubing

– undefined switching states

3. Installation

SPC200-COM-IBS 0503a

3-3