4 operating modes – Festo Кабели и принадлежности User Manual
Page 19
1.4
Operating modes
Whether for control via an I/O module or via a field bus,
the SPC200 offers the following operating modes for
processing the stored NC programs:
•
start/stop mode
•
record select mode
The desired operating mode can be set with the control
panel or with WinPISA. Detailed information on the
operating modes can be found in the user manual for
the SPC200.
The SPC200 communicates with the INTERBUS mas-
ter via the internal I/O address ranges (internal
input/output addresses) of the field bus module. De-
pending on the operating mode used, field bus module
type SPC200-COM-IBS provides the following I/O bits
for communication with the INTERBUS master:
Operating mode
I/O address range of field bus
module type SPC200-COM-IBS
Start/Stop
I10.0 - I13.15
*)
**)
Q10.0 - Q13.15
*)
**)
Record select
I10.0 - I11.15
*)
Q10.0 - Q10.15
*)
*)
Address specification as seen by the SPC200
**)
1-4 process data words can be configured
CAUTION
The outputs of the INTERBUS master are mapped
on internal inputs of the field bus module or of the
SPC200.
1. System summary
SPC200-COM-IBS 0503a
1-7