beautypg.com

Festo Кабели и принадлежности User Manual

Page 21

background image

When a field bus module is used:

the address ranges 0.0 ... 0.15 remain unused.
These address ranges, which serve without field bus
module for controlling the SPC200, are not available.

maximum 3 I/O modules can be inserted. These pro-
vide exclusively freely programmable I/Os in the
operating mode start/stop.

The address assignment when a field bus module is
used is shown in the table below.

Module

Maximum address range

-

1)

I0.0 ...I0.9

1)

Q0.0 ... Q0.7

1)

I/O modules on first
axis interface string

I1.0 ... I1.15

Q1.0 ... Q1.15

First I/O module

I2.0 ... I2.9

Q2.0 ... Q2.7

I/O modules on second
axis interface string

I3.0 ... I3.15

Q3.0 ... Q3.15

Second I/O module

I4.0 ... I4.9

Q4.0 ... Q4.7

Third I/O module

I5.0 ... I5.9

Q5.0 ... Q5.7

Field bus module

I10.0 ... I13.15

Q10.0 ... Q13.15

1) Address range 0.0 ... 0.15 is not available if a field bus module

is used

The functions of the internal input and output bits of the
field bus module, as well as the permitted NC
commands, depend on the operating mode set.
Detailed information on this can be found in the user
manual for the SPC200.

1. System summary

SPC200-COM-IBS 0503a

1-9