the configuration of the process data channel in
record select mode: 2I / 2O words
In the record select operating mode the field bus
module communicates fixed with 4 input and 4 output
bytes
*)
. The process data channel comprises 32
bits.
•
the configuration of the process data channel in
start/stop mode: 1I/O ... 4 I/O words (default 1 I/O)
In the start/stop operating mode further freely
programmable inputs/outputs can be configured, in
addition to the I/O word for the control signals
*)
. The
process data channel then comprises 16, 32, 48
or 64 bits..
*)
The meaning of the I/O bytes is explained in more
detail in Chapter 4.2.2.
Downloading the field bus parameters
– The parameters of the field bus module are always
loaded into the SPC200 within the complete project.
A system reset then takes place. A separate
download of the field bus parameters is not possible.
– The field bus module is ready for operation on the
INTERBUS when the LED “RD” lights up (the
initialization phase of the SPC200 is then concluded).
Control panel
Configuration of the process data channel can also be
carried out with the control panel of the SPC200. To do
this switch to the menu "CONFIG.SYSTEM" and select
"FIELDBUS" therein.
4. Commissioning
SPC200-COM-IBS 0503a
4-11