Figure 4: system utilities tab (configuration) – Allied Telesis AT-S63 User Manual
Page 36
Chapter 1: Basic Switch Parameters
36
Section I: Basic Operations
2. From the Configuration menu, select the Utilities option.
The Utilities page is displayed with the System Utilities tab selected by
default, as shown in Figure 4.
Figure 4. System Utilities Tab (Configuration)
3. Click the Reboot Switch After Resetting to Defaults checkbox.
4. Click Apply.
The web browser displays the following prompt:
This page may no longer be available while the switch
reboots. Do you want to continue?
5. Click OK to continue or Cancel to cancel the procedure.
If you select OK, the switch resets and returns all values to the default
settings. After the reset is complete, you must establish a new
management session if you want to continue managing the unit,
probably from a local management session.
As mentioned at the start of this procedure, returning a switch to is
default settings does not alter the contents of the active boot
configuration file. To return the file to the default settings, you must
save the current switch settings after you establish a new
management session with the switch. Otherwise, the switch returns to
its previous parameter settings the next time you reset or power cycled
the unit.