Wait until the end of the pre-heating

procedure. If the air temperature is

too low the unit will remain disabled

and the following message will be

shown:

Address : 1

DE-ICE PROCEDURE

------------------------

SYSTEM BLOCKED

TEMPERATURE TOO LOW

------------------------

PROBLEM

Error E1-AUTOPAN WITHOUT

LIMITS.

CAUSE

The two presets used as limits have

not been programmed.

SOLUTION

Program the two presets and then

update the Autopan configuration

menu (11.2 Saving the current

position (Preset), page 62 and 9.1.6.7

Autopan Menu, page 42).

PROBLEM

Error E2-WIPER BLOCKED.

CAUSE

The wiper is either jammed or

broken.

SOLUTION

Check that the wiper is free to

move; if the problem persists, seek

assistance.

PROBLEM

Error E3-PATROL WITHOUT

PRESET or error E4-PATROL, 1

PRESET ONLY.

CAUSE

The presets have not been

programmed.

SOLUTION

Program two or more presets and

then update the Patrol configuration

menu (11.2 Saving the current

position (Preset), page 62 and 9.1.6.6

Patrol Menu, page 42).

PROBLEM

Error E5-IR TEMP. TOO HIGH or

error E6-IR FAULT.

CAUSE

The infrared illuminator is not

working properly.

SOLUTION

Seek assistance.

PROBLEM

Error E7-PRST. NOT

CONFIGURED.

CAUSE

Recalling of a non programmed

preset.

SOLUTION

Save the preset using the relative

control (11.2 Saving the current

position (Preset), page 62).

PROBLEM

Error E8-TOUR NOT

CONFIGURED.

CAUSE

Recalling of a non configured Tour.

SOLUTION

Save the Tour using the relative

control (11.6 Recalling a pattern

(Tour), page 63).

PROBLEM

Error E9-TEMP. TOO LOW.

CAUSE

The environment temperature is

too low.

SOLUTION

The movements of the P&T unit

is blocked to prevent mechanical

damage.