7.2.6 Serial line terminations

To set the serial line terminations operate on DIP

2.
The board has two DIP switches used to configure the

serial line terminations (120 Ohm) (Tab. 7, page 23).
Every peripheral that is situated at the end of a line

must be terminated using the appropriate dip-switch

in order to prevent signal reflection and distortion.
Dip-switches 7 and 8 terminate serial lines RS-485-1

and RS-485-2 respectively.
The serial lines are ended with the following dip-

switches: RS-485-1/RS-485-2, dip-switch 7 and 8.
The serial lines are ended with dip-switches.
Serial line: RS-485-1, RS-485-2
Dip-switch: SW 7, SW 8

SERIAL LINE TERMINATIONS (DIP 2) AND

CONNECTIONS

Description

SW 1-2-3-4-5-6

SW 7

SW 8

Configur

ation

Serial line

terminations

ON RS485-2 termination

enabled

OFF RS485-2 termination

disabled

ON –

RS485-1 termination

enabled

OFF –

RS485-1 termination

disabled

Tab. 7

7.2.7 Protocol configuration

The protocol must be set to NETWORK in

case of versions with digital video encoder.

To set the protocol operate on DIP 1.

1 2

3 4 5

6 7

8

9

0

1 2

3 4 5

6 7

8

9

0

1 2

3 4 5

6 7

8

9

0

0A

ON

1 2

3 4

5

6 7

8

U2

U1

U3

D

IP

3

D

IP

5

D

IP

4

1

2

3

4

DIP 1

Fig. 23

Video positioning systems of the P&T can be

controlled by a range of protocols.

SETTING THE PROTOCOL (DIP 1)

SW 1 SW 2 SW 3 SW 4 Protocol
ON

OFF

ON

OFF

PANASONIC

OFF

OFF

ON

OFF

ERNITEC

OFF

ON

OFF

OFF

SENSORMATIC

ON

OFF

OFF

OFF

PELCO D

OFF

OFF

OFF

OFF

VIDEOTEC MACRO

OFF

ON

ON

OFF

NETWORK

Tab. 8