MNVCNXPTZT_1343_EN

7.2.8 Address configuration

To set the address operate on DIP 3, DIP 4 and DIP

5.

1 2

3 4 5

6 7

8

9

0

1 2

3 4 5

6 7

8

9

0

1 2

3 4 5

6 7

8

9

0

0A

ON

1 2

3 4

5

6 7

8

U2

U1

U3

D

IP

3

D

IP

5

D

IP

4

1

2

3

4

Fig. 24

Address setting example:
• Unit number: 431
• Dip-switch 3 (hundreds): 4
• Dip-switch 4 (tens): 3
• Dip-switch 5 (units): 1

7.2.9 Configuration of the version with

IP board

The unit can be configured in one way only. Set the

DIP exactly as shown in the table.

CONFIGURATION OF THE VERSION WITH IP BOARD

Address

1

Protocol

VIDEOTEC MACRO (Network,

versions with a digital video

encoder)

Baud rate

38400 (9600, versions with a

digital video encoder)

Serial line

RS-485, unidirectional

Serial line termination (1)

ON

Serial line termination (2)

ON

Tab. 9

Once the dip-switches are configured, the P&T IP

parameters can be configured (9.2 Sofware interface,

page 52).

7.2.10 Closing the configuration door

After you have set your parameters re-connect the

board on the plug of the connection board.