MNVCNXPTZT_1343_EN

9.3.14 Factory Default

To restore the factory settings relative to the network,

user access and camera configuration follow this

procedure:
• Switch off the unit.
• Connecting the reset kit to the encoder that must

be reset.

• Power the unit. Wait for 2 minutes.
• Keep the button pressed for 15 seconds.
• Switch off the unit.
• Remove the reset kit.
• Power the unit.

Fig. 120

10 Accessories

For further details on configuration and

use, refer to the relative manual.

10.1 Washer

The P&T can be equipped with an external pump that

supplies water for the glass to be cleaned.
To complete the installation of the washer use the kit

supplied.

Fig. 121

For further information refer to the

relative chapter (11.9 Enabling the washer

(Washer), page 64).