Input/output functions – High Country Tek DVC80 User Manual
Page 54

P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools
Page | 54
Name.ProI
Process Proportional Term Constant “I”
0 – 255
Name.ProItime
Update / Integration Time
0.0 to 650.00 s
Name.Cur
Current actual * CurGain = amps
0 – 3.5 amps
Name.RampCur
Current ramped Currend*CurGain= amps
0 – 3.5 amps
Name.CurErr
Current Error = RampCur – Cur
16 bit signed integer
Name.CurSumErr
Current Error accumulated over time
0 – 65535
Name.CurP
Current Proportional Term Constant “P”
0 – 255
Name.CurI
Current Proportional Term Constant “I”
0 – 255
Name.MinCurA
Minimum Current Coil A *.001 = amps
0 – 3.5 amps
Name.MaxCurA
Maximum Current Coil A *.001 = amps
0 – 3.5 amps
Name.MinCurB
Minimum Current Coil B *.001 = amps
0 – 3.5 amps
Name.MaxCurB
Maximum Current Coil B *.001 = amps
0 – 3.5 amps
Name.Config
Configuration Word – Output, Process,
Coil
Status LED
Name Description
Range
BlinkCode
The Status LED blinks the amount of times equal to the number
written to this location. When the blinking is done, the value for this
location will be 0.
0 to 65535
Input/Output Functions
Name Description
Range
Name.In
Changing this variable will update the "Name.Out"
variable by the BIOS after a delay of 10ms
0% to 100%
Name.Out
The Output of the Transfer Function
0% to 100%
Name.X0
The X0 of the input/output function
0% to 100%
Name.X1
The X1 of the input/output function
0% to 100%
Name.X2
The X2 of the input/output function
0% to 100%
Name.X3
The X3 of the input/output function
0% to 100%
Name.X4
The X4 of the input/output function
0% to 100%
Name.X5
The X5 of the input/output function
0% to 100%
Name.X6
The X6 of the input/output function
0% to 100%
Name.X7
The X7 of the input/output function
0% to 100%
Name.Y0
The Y0 of the input/output function
0% to 100%
Name.Y1
The Y1 of the input/output function
0% to 100%
Name.Y2
The Y2 of the input/output function
0% to 100%
Name.Y3
The Y3 of the input/output function
0% to 100%
Name.Y4
The Y4 of the input/output function
0% to 100%
Name.Y5
The Y5 of the input/output function
0% to 100%
Name.Y6
The Y6 of the input/output function
0% to 100%
Name.Y7
The Y7 of the input/output function
0% to 100%
Power Supply
Name
Description
Supply
The Power Supply voltage. The value returned is in units of supply volts (sv)
Temperature
Name
Description
DVC_Temperature Internal DVC5/7 controller temperature. The value returned is in units of
degrees C + 40. Therefore, –40 C is returned as 0.
Continuous Counter