High Country Tek DVC80 User Manual
Page 50

P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools
Page | 50
Digital Input
Name Description
Range
Name
1
Set/Get the state of the switch
False or Off, True or
On
Name.RealRPM
The Unsigned Integer Value of the RPM. For Pulse
inputs Only
0 to 9999
Name.PulseTimeout
Get/Set Pulse Timeout for Loss of Signal
0 to 65535
Name.PulsesPerRev
Get/Set Pulses Per Revolution
0 to 9999
Name.Counter
Get/Set Unsigned Integer Value of the Counter.
Pulse inputs Only
0 to 65535
Name.LOS
Loss of Signal flag set after time out. For Pulse
inputs Only
False (Pulses ok),
True (No Pulse Input)
Universal and Analog Input
Name Description
Range
Name
1
Get 0 to 100% regardless of direction
0% to 100%
(Min Volts to Center
Volts)
NameLo
1
Get 0 to 100% of Min to (Center - Deadband)
only if Center is enabled
0% to 100%
(Center Volts to Max
Volts)
NameHi
1
Get 0 to 100% of (Center + Deadband) to Max
only if Center is enabled
0% to 100%
Name.Dir
Get the Upper or Lower Side of the Analog
Input only if Center is enabled.
Lower Side voltage is lower than the Upper
Side
False (Lower Side), True
(Upper Side)
Name.RawVolts
Volts or mAmps (ma = universal input ma
select)
0 to 1023 * Scale
2
Name.RefVolts
Reference Volts = RefVolts * .00489
0 to 1023
Name.RampVolts
Ramped Volts = RampVolts * Scale Factor
0 to 1023 * Scale
2
Name.MinVolts
When Name = 0% (i.e. Center not enabled)
0 to 1023 * Scale
2
Name.MaxVolts
When Name = 100%
0 to 1023 * Scale
2
Name.MinLimit
Threshold for Name.MinF
0 to 1023 * Scale
2
Name.MaxLimit
Threshold for Name.MaxF
0 to 1023 * Scale
2
Name.RefMinLimit
Threshold for Name.MinRF
0 to 1023 * Scale
2
Name.RefMaxLimit
Threshold for Name.MaxRF
0 to 1023 * Scale
2
Name.CenterVolts
Where Center Volts
0 to 1023 * Scale
2
Name.Deadbandv
Plus and minus volts about CenterVolts
0 to 1023 * Scale
2
NameX.RampUp
RampUp * .01 = Time Min to Max (Seconds)
0.0 to 65.00 s
NameX.RampDown
RampDown * .01 = Time Max to Min (Seconds)
0.0 to 65.00 s
NameX
Where NameX = NameLo, NameHi if Center is
enabled NameX = Name if Center is not
enabled
Name.MinF
Status Flag set if Voltage is less than Min Limit
False (ok), True (Outside
Limit)
Name.MaxF
Status Flag set if Voltage is greater than Max
Limit
Range: False (ok), True
(Outside Limit)
Name.MinRF
Status Flag set if Voltage is less than
Reference Min Limit
False (ok), True (Outside
Limit)
Name.MaxRF
Status Flag set if Voltage is greater than
Reference Max Limit
False (ok), True (Outside
Limit)