High Country Tek DVC80 User Manual
Page 53

P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools
Page | 53
from 100% to 0%)
Name.Frequency
Set PWM frequency
0 to 1000 for 0 to 100hz
Name.Dutycycle
Ser PWM dutycycle
0 to 1023 for 0 to 100%
Name.Freqerror
Returns error 1 = Frequency error,
2 means duty cycle error
HSEvenName
Set the Bang-bang Coil to On or Off
Off, On
HSEven#Name.Short
Get the Coil Flag for Short Status
Off [Coil Ok], On [Coil
Short]
HSEven#Name.Open
Get the Coil Flag for Open Status
Off [Coil Ok], On [Coil
Open]
HSOddName
Set the Bang-bang Coil to On or Off
Off, On
HSOdd#Name.OpenDisable
Set the Disable Coil Open Detection
0 [Enabled], 1 [Disabled]
HSOdd#Name.Short
Get the Coil Flag for Short Status
Off [Coil Ok], On [Coil
Short]
HSOdd#Name.Open
Get/Set the Coil Flag for Open Status
Off [Coil Ok], On [Coil
Open]
Name.Cur
Current actual * CurGain = amps
0 – 3.5 amps
Name.RampCur
Current ramped Currend*CurGain= amps
0 – 3.5 amps
Name.CurErr
Current Error = RampCur – Cur
16 Signed Integer
Name.CurSumErr
Current Error accumulated over time
0 – 65535
Name.CurP
Current Proportional Term Constant “P”
0 – 255
Name.CurI
Current Proportional Term Constant “I”
0 – 255
Name.MinCurA
Minimum Current Coil A *.001 = amps
0 – 3.5 amps
Name.MaxCurA
Maximum Current Coil A *.001 = amps
0 – 3.5 amps
Name.Config
Configuration Word – Output, Process,
Coil
Output Group Selected as PWM Disabled
Name Description
Range
HSEvenName
Set the Bang-bang Coil to On or Off
Off, On
HSEven#Name.OpenDisabl
e
Set the Disable Coil Open Detection
0 [Enabled], 1 [Disabled]
HSEven#Name.Short
Get the Coil Flag for Short Status
Off [Coil Ok], On [Coil
Short]
HSEven#Name.Open
Get the Coil Flag for Open Status
Off [Coil Ok], On [Coil
Open]
HSOddName
Set the Bang-bang Coil to On or Off
Off, On
HSOdd#Name.OpenDisabl
e
Set the Disable Coil Open Detection
0 [Enabled], 1 [Disabled]
HSOdd#Name.Short
Get the Coil Flag for Short Status
Off [Coil Ok], On [Coil
Short]
HSOdd#Name.Open
Get/Set the Coil Flag for Open Status
Off [Coil Ok], On [Coil
Open]
Enable Process PI Variables
The Name field is the Low-Side name. The default variable name is replaced with the specified name.
Name Description
Range
Name.Setpoint
The desired % set point position for the
output
0 to 100%
Name.Feedback
The % feedback position for the output
0 to 100%
Name.ProErr
Error = Set point – Feedback
16 bit signed integer
Name.ProSumErr
Error accumulated over time
0 – 65535
Name.ProP
Process Proportional Term Constant “P”
0 – 255