High Country Tek DVC80 User Manual
Page 52

P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools
Page | 52
Output Group Selected as Single Coil High-Side
Name Description Range
Name
Set the state Current Target or
Process in percentage of min to max
current
0 = 0 Current, .1% = Min Current,
and 100% = Max Current
0% to 100%
Name.Enable
Set the PWM to 0 or enable the
PWM
True [PWM Enabled], False
[PWM = 0]
Name.Short
Get the Coil Flag for Short Status
Off [Coil Ok], On [Coil Short]
Name.Open
Get the Coil Flag for Open Status
Off [Coil Ok], On [Coil Open]
Name.Rampup
Set the ramp up rate (time to travel
from 0% to 100%)
0.0 to 65.00 s
Name.Rampdown
Set the ramp down rate (time to
travel from 100% to 0%)
0.0 to 65.00 s
HSEvenName
Set the Bang-bang Coil to On or Off
Off, On
HSEven#Name.Short
Get the Coil Flag for Short Status
Off [Coil Ok], On [Coil Short]
HSEven#Name.Open
Get the Coil Flag for Open Status
Off [Coil Ok], On [Coil Open]
HSOdd#Name.OpenDisable
Set the Disable Coil Open Detection
0 [Enabled], 1 [Disabled]
HSOdd#Name.Short
Get the Coil Flag for Short Status
Off [Coil Ok], On [Coil Short]
HSOdd#Name.Open
Get/Set the Coil Flag for Open
Status
Off [Coil Ok], On [Coil Open]
Name.Cur
Current actual * CurGain = amps
0 – 3.5 amps
Name.RampCur Current
ramped
Currend*CurGain=
amps
0 – 3.5 amps
Name.CurErr
Current Error = RampCur – Cur
16 Signed Integer
Name.CurSumErr
Current Error accumulated over time
0 – 65535
Name.CurP
Current Proportional Term Constant
“P”
0 – 255
Name.CurI
Current Proportional Term Constant
“I”
0 – 255
Name.MinCurA
Minimum Current Coil A *.001 =
amps
0 – 3.5 amps
Name.MaxCurA
Maximum Current Coil A *.001 =
amps
0 – 3.5 amps
Name.Config
Configuration Word –Output,
Process, Coil
Output Group Selected as Single Coil Low-Side
Name Description
Range
Name
Set the state Current Target or Process in
percentage of min to max current
0 = 0 Current, .1% = Min Current, and
100% = Max Current
0% to 100%
Name.Enable
Set the PWM to 0 or enable the PWM
True [PWM Enabled],
False [PWM = 0]
Name.Short
Get the Coil Flag for Short Status
Off [Coil Ok], On [Coil
Short]
Name.Open
Get the Coil Flag for Open Status
Off [Coil Ok], On [Coil
Open]
Name.Rampup
Set the ramp up rate (time to travel from
0% to 100%)
0.0 to 65.00 s
Name.Rampdown
Set the ramp down rate (time to travel 0.0 to 65.00 s