High Country Tek DVC80 User Manual
Page 51

P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools
Page | 51
Name.LOS
Loss of Signal flag set after time out. For
Universal Pulse inputs Only
False (Pulses ok), True (No
Pulse Input)
Name.RealRPM
The Unsigned Integer Value of the RPM. For
Universal Pulse inputs Only
0 to 9999
Name.Counter
Get/Set Unsigned Integer Value of the Counter.
Universal Pulse inputs Only
0 to 65535
Name.PulsesPerRev
Get/Set Pulses Per Revolution
0 to 9999
Output Group Selected as Dual Coil High-Side
Name Description Range
(Low-Side/PWM) Name
Set the state Current Target or
Process in percentage of min to max
current
0% to 100%
Name.Dir
Set the coil to be PWM’d, *(use High
Side names to set the direction)
High-Side Odd # Name / High
Side Even # Name
Name.Enable
Set the PWM to 0 or enable the PWM
True [PWM Enabled], False
[PWM = 0]
Name.Short
Get the Coil Flag for Short Status
Off [Coil Ok], On [Coil Short]
Name.Open
Get the Coil Flag for Open Status
Off [Coil Ok], On [Coil Open]
HSEven#Name.Rampup
Set the ramp up rate (time to travel
from 0% to 100%)
0.0 to 65.00 s
HSEven#Name.Rampdown
Set the ramp down rate (time to travel
from 100% to 0%)
0.0 to 65.00 s
HSEven#Name.Short
Get the Coil Flag for Short Status
Off [Coil Ok], On [Coil Short]
HSEven#Name.Open
Get the Coil Flag for Open Status
Off [Coil Ok], On [Coil Open]
HSOdd#Name.Rampdown
Set the ramp down rate (time to travel
from 100% to 0%)
0.0 to 65.00 s
HSOdd#Name.Short
Get the Coil Flag for Short Status
Off [Coil Ok], On [Coil Short]
HSOdd#Name.Open
Get the Coil Flag for Open Status
Off [Coil Ok], On [Coil Open]
Name.Cur
Current actual * CurGain = amps
0 – 3.5 amps
Name.RampCur
Ramped Current*CurGain= amps
0 – 3.5 amps
Name.CurErr
Current Error = RampCur – Cur
16 bit signed integer
Name.CurSumErr
Current Error accumulated over time
0 – 65535
Name.CurP
Current Proportional Term Constant
“P”
0 – 255
Name.CurI
Current Proportional Term Constant
“I”
0 – 255
Name.MinCurA
Minimum Current Coil A *.001 = amps
0 – 3.5 amps
Name.MaxCurA
Maximum Current Coil A *.001 =
amps
0 – 3.5 amps
Name.MinCurB
Minimum Current Coil B *.001 = amps
0 – 3.5 amps
Name.MaxCurB
Maximum Current Coil B *.001 =
amps
0 – 3.5 amps
Name.Config
Configuration Word –Output,
Process, Coil
1
Name is the actual name entered in the Input/Output configuration window.
2
Scale depends on Input Range (0 to 5 =.00489, 0 to 10 = .00977, 0 to 25ma = 0.02158 )