8. OUTPUTS: (Output type and quantity, model dependent)

Solid-State:

NPN Open Collector: I

SNK

= 100 mA max. @ V

OL

= 1.1 VDC max.;

V

OH

= 30 VDC max.

PNP Open Collector: I

SRC

= 100 mA max.(See note);

V

OH

= 12 VDC ±15% (using internal supply); V

OH

= 13 to 30 VDC

(using external supply).
Note: The internal supply of the C48C can provide a total of 100 mA for
the combination of sensor current and PNP output sourcing current.
The supply voltage is +12 VDC (±15%), which will be the PNP output
voltage level when using only the internal supply.

If additional PNP output sourcing current or a higher output voltage

level is desired, an external DC supply may be connected between the
“DC Out/In” and “Comm.” terminals. This supply will determine the
PNP output voltage level, and must be in the range of +13 to +30 VDC.

An external supply can provide the additional output sourcing current

required in applications where two or more outputs are “ON”
simultaneously. However, the maximum rating of 100 mA per individual
output must not be exceeded, regardless of external supply capacity.

Relay: Form A contact, Rating = 5 A @ 250 VAC, 30 VDC (resistive load),

1/10 HP @ 120 VAC (inductive load)
Relay Life Expectancy: 100,000 cycles min. at max. load rating

Programmable Timed Output: User selectable output time resolution.

0.01 Second Resolution: 0.01 to 99.99 sec,

± 0.01% +20 msec max.

(Prescalers less than 2)

0.1 Second Resolution: 0.1 to 999.9 sec, ±100 msec

(Prescalers less than 2)

Note: For Prescaler values above 2, the timed delay output is affected by

the count speed (rate).

9. RS485 SERIAL COMMUNICATIONS (Optional): Up to 32 units can be

connected.
Baud Rate: Programmable from 1200 to 9600 baud
Address: Programmable from 0 to 99
Data Format: 10 Bit Frame, 1 start bit, 7 or 8 data bits, 1 or No Parity bit,

and 1 stop bit

Parity: Programmable for Odd (7 data bits), Even (7 data bits), or None (8

data bits)

10. CERTIFICATIONS AND COMPLIANCES:

SAFETY

UL Recognized Component, File #E137808, UL508, CSA C22.2 No. 14

Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.

Type 4X Indoor Enclosure rating (Face only), UL50
IEC 1010-1, EN 61010-1: Safety requirements for electrical equipment for

measurement, control, and laboratory use, Part 1.

IP65 Enclosure rating (Face only), IEC 529

ELECTROMAGNETIC COMPATIBILITY

Notes:
AC VERSIONS
1. A power line filter, RLC#LFIL0000 or equivalent, was installed when the

unit was DC powered.

DC VERSIONS

To insure compliance with the EMC standards listed above, do not connect
any wires from the terminal(s) labeled “COMM.” to the “DC-” supply
terminal (12), when powering the unit from a DC supply.

Refer to EMC Installation Guidelines section of the manual for additional

information.

-41-

Enclosure class A

EN 55011

RF interference

Emissions to EN 50081-2

Level 3; 10 V/m

ENV 50204

Simulation of cordless telephone

150 KHz - 80 MHz

Level 3; 10 V/rms

EN 61000-4-6

RF conducted interference

Level 3; 2 Kv power

Level 4; 2 Kv I/O

EN 61000-4-4

Fast transients (burst)

80 MHz - 1 GHz

Level 3; 10 V/m

EN 61000-4-3

Electromagnetic RF fields

Level 3; 8 Kv air

Level 2; 4 Kv contact

EN 61000-4-2

Electrostatic discharge

200 Hz, 50% duty cycle

Immunity to EN 50082-2

900 MHz ± 5 MHz