There are several ways to limit the programming of parameters from the front

panel keypad. The Accessible Value parameters are used with the Program
Disable DIP switch and an external programmable User Input selected for

Pro.dis

to limit programming. To enter the programming mode, a code number

may need to be entered, depending on the Program Disable Setting. Front Panel
Function Key F1 cannot be selected for program disable. The following table
describes the possible program disabling functions.

-14-

Front Panel Accessible Functions With Program Disable

PGM.DIS.

SWITCH

USER INPUT TERMINAL

PROGRAM CODE

NUMBER

PROTECTED VALUE

MENU

OPERATOR ACCESS AT

MAIN DISPLAY

PROGRAM

DISABLE LEVEL

PROGRAMMING

ENABLED

OFF

INACTIVE or Not
Programmed for Pro.dis

ALL

No

All displayed values
changeable

None

Yes

OFF

ACTIVE

0

No

Per Access Privileges
programmed

Level 1

No

OFF

ACTIVE

1 to 99

Yes

W/code

Per Access Privileges
programmed

Level 1

No

OFF

ACTIVE

100 to 199

No

Per Access Privileges
programmed

Level 1

Yes

W/code

ON

INACTIVE or Not
Programmed for Pro.dis

0

No

Per Access Privileges
programmed

Level 1

No

ON

INACTIVE or Not
Programmed for Pro.dis

1 to 99

Yes

W/code

Per Access Privileges
programmed

Level 1

No

ON

INACTIVE or Not
Programmed for Pro.dis

100 to 199

No

Per Access Privileges
programmed

Level 1

Yes

W/code

ON

ACTIVE

ALL

No

Viewable only

Level 2

No