C2 asn, Total, Batch – Red Lion C48C User Manual

Page 26: Counter 2 assignment (batch model only)

background image

Counter 2 Assignment (Batch Model only)

This parameter configures Counter 2 to function as a

Batch or Total Counter.

Counter 2 Count Direction when configured as a Totalizer

When Counter 2 is assigned to Total, the Prescaler value is limited to
1.00000 or less. For Prescaler values less than one, that are not evenly
divisible into the Preset 2 value, the Total count incurs an accumulating
error of up to 1 count for every auto reset cycle of Counter 1. In effect,
it does not accumulate the “total” amount of material used, it
accumulates the “total” number of counts registered in Counter 1.

DUAL PRESET/ BATCH COUNTER 1 OPERATING MODES

-20-

Manual

RESET TYPE

Auto

RESET

T

o

Zero

T

o

Preset

2

at
T

imed

02

End

OUTPUT 1

Latched

Ti

m

e

d

O1

Off

at

O2

OUTPUT 2

Latched

T

imed

1

2

3

4

5

6


7

8

9

10


11

12


13

14


15

16


17

18

MODE#

Reversed

Count

Direction

Up

Dn

Up

Dn

Normal Count

Direction

Dn

Up

Dn

Up

Count Reset

Modes

Reset to

P3

Reset to

0

Reset to

P2

Reset to

0

NOTES

RESULTANT COUNTER 2

COUNT DIRECTION FOR

C2 OPERATING MODE

COUNTER 1 COUNT

DIRECTION FOR C1

OPERATING MODE

Counter 2 operates as a totalizing counter. The totalizer counts
whenever Counter 1 increments or decrements. The count direction is
determined by; Counter 1 count direction, Counter 1 Operating “Reset
to” mode, and the Counter 2 Operating “Reset to” mode.

totAL

Counter 2 operates as a batch counter. A batch is counted when Output
2 of Counter 1 is triggered. The Count direction is determined by the
Counter 2 Operating Mode.

bAtch

DESCRIPTION

MODE

C2 ASn

bAtch