beautypg.com

Ag Leader Base Station Configuration and Utilities User Manual

Page 8

background image

2202 South Riverside Drive, Ames, IA 50010

Phone: 515-232-5363 Internet: http://www.agleader.com

p/n 4002138

12/22/2009 Rev A

8


6. Select proper Com port and click on “Base Location Config” tab. Following screen will appear.

Figure 7

7. Refresh the web page by hitting F5 key on key board, till base station calculates position and shows it as

follow. The line “SPS average for 28 sec” indicates that base has averaged position for 28 seconds. This
time will increase every time you refresh web page.

8. Now disconnect PC and leave base station powered. It will continue average the position.

9. Come back after 24 hours. Without powering off base station, connect PC again as above and go to the

same web page. It should now show the time the base has been averaging.


10. Click “Add Average Position as New Location” to get page like this.