beautypg.com

HP Insight Management-Software User Manual

Page 125

background image

For information on enclosure problems, see

“Enclosure has a hardware failure and must be

replaced” (page 131)

.

In a redundant environment, the failover between active and standby VC module is taking
place.

To correct this issue:
1.

Verify that the failover between the active and standby VC module is taking place.

2.

Wait a few minutes until the failover completes, and then try again.

3.

Log into VCM (https://). A status of Active Virtual Connect Manager not
at this IP address might appear.

4.

You must also rediscover the Onboard Administrator related to this VC Domain again by
selecting Systems Insight Manager menu Options

→Identify System or Options→Discovery.

Verify firmware update is in progress and wait a few minutes until the update is completed.

Log into the VCM (https://), and verify the VC Domain firmware status, click
Domain Settings

→Firmware Management.

Run an Systems Insight Manager discovery to identify the new VC Domain IP address and
perform the operation again.

If you perform an operation that changes the VC Domain status to Connectivity failure, VCEM
will check the connectivity using the information from Systems Insight Manager nodes after
the operation completes.

Remove the VC Domain from the VC Domain Group, and run the Systems Insight Manager
discovery task to identify the new VC Domain IP address.

Break the external manager lock, and then release these MAC and WWN address ranges
as follows:
1.

Telnet in to VCM using an SSH connection such as SSH Administrator@xxx.xxx.xxx.xxx,
where xxx.xxx.xxx.xxx is the VC Domain IP address.

2.

To determine the user name of the external manager account, from the VCM command
prompt, enter show external-manager. For this example, assume the user name
returned was xyz.

3.

To disable the account, from the VCM command prompt, enter set external-manager
Username=xyz Enabled=false

.

Perform the following:

To remove the account and release the VC Domain from VCEM control, from the VCM
command prompt, enter:

remove external-manager Username=xyz

mactype= MacStart=<> MacEnd=<>

wwnType= WwnStart=<> WwnEnd=<>

serverIdType= serverIdStart=<>

serverIdEnd=<>

NOTE:

The option “-quiet” is available to suppress user confirmation prompts. This

option is useful for scripting operations. This option is available for VC firmware for the
disable account

, remove the account, and release ranges commands.

Cannot resynchronize VC Domain that is in Configuration Mismatch state

Attempting to resynchronize a VC Domain that is in Configuration Mismatch results in a failed job,
and the following message appears:

Unable to import the MAC, WWN or VSN addresses. Possible reasons include

Cannot resynchronize VC Domain that is in Configuration Mismatch state

125

This manual is related to the following products: