HP Insight Management-Software User Manual
Page 29
◦
Maximum Link Connection Speed
◦
Network Access Groups (associated with this network)
•
For each Fibre Channel SAN Fabric:
Fabric name
◦
◦
Fabric port location
◦
Configuration speed
•
Number of Fibre Channel SAN Fabrics configured in the VC Domain
To add an unconfigured VC Module to a VC Domain Group, the following items must be identical:
•
Interconnect bays location and model
•
Enclosure model
•
Uplinks of the network and Fibre Channel SAN Fabric
•
Power state of the VC Modules
VC 3.5x feature that must be disabled in a VC Domain to be part of a VC Domain
Group with VC firmware 3.3x
Extra FC or FCoE connections are not supported.
Do not configure server profiles with more FC SAN Connections or FCoE Connections than
redundant connections per Virtual Connect Fibre Channel or Virtual Connect Flex Fabric modules
available in the VC Domain. The extra FC SAN or FCoE connections display additional connections
pointing to bays 1 and 2 (in the FCoE connection list) and bays 3 and 4 (in the FC connection list,
for C3000 enclosures only) in the “Connected To” column. See
for more
information.
Figure 11 Removing FC and FCoE connections in 3.5x
To disable this feature, delete the additional FC SAN connections or FCoE connections (that exceeds
the 4 redundant connections to each Virtual Connect Fibre Channel/Virtual Connect FlexFabric
Module) from the server profile.
Requirements for adding a VC Domain to a VC Domain Group
29