Vcm shows an incorrect address for vcem – HP Insight Management-Software User Manual

Page 120

background image

1.

Select the VCEM Server Profiles tab.

2.

Select the server profile that is presenting the problem.

3.

Click Edit.

4.

In the boot target configurations table, change all the target LUN fields to be within the allowed
ranges (either a 3-digit decimal between 0-255, or a 16-digit hexadecimal between 0 and
FFFFFFFFFFFFFFFF).

5.

Click OK.

6.

Monitor the job progress until it is complete.

After the operation completes, you can perform move and failover operations on the server profile.

Error popup appears when you select HP predefined ranges during remove
VC Domain from group or delete VC Domain Group operations

Using the web browser in the Japanese language causes an error popup to appear when you
select a HP pre-defined range to be used by a VC Domain that is being removed from a VC Domain
Group.

To resolve the issue:
1.

Clear the Use Pre-defined range check box.

2.

Enter the From and To values for the desired range in the text boxes.

3.

Click OK. Wait until the process completes.

Unable to complete or cancel VC Domain maintenance after enabling
Expanded VLAN Capacity in VC Domains

VCEM 7.1 is able to manage VC Domains with Expanded VLAN capacity (Extended Mapped
VLAN) enabled, but VCM firmware version 3.3x or later does not allow you to easily revert back
from Expanded VLAN capacity mode to Legacy capacity mode.

Before applying Expanded VLAN capacity to a VC Domain 3.3x or later during Maintenance
Mode, make sure the VC Domain Group that the VC Domain belongs to is running firmware mode
3.3x or higher (this is a VCEM rule). If you change a VC Domain 3.3x to Expanded VLAN Capacity
and the VC Domain Group firmware mode is lower than 3.3x, the Complete Maintenance Mode
operation will fail, because VCEM will detect an enabled feature (Expanded VLAN capacity) not
supported by the other VC Domains (with older firmware). The VC Domain will remain in
Maintenance Mode status and VCEM will not be able to complete or cancel the maintenance
operation. To complete or cancel the maintenance operation, you must first remove the VC Domain
with Expanded VLAN capacity from the Domain Group.

VCM shows an incorrect address for VCEM

When you log into the VCM while under VCEM control, the following message is displayed:

VC Domain locked by Virtual Connect Enterprise Manager [x.x.x.x]

The x.x.x.x in the message is an incorrect IP address for VCEM.

NOTE:

The incorrect IP address does not have any impact on VCEM management of VCM.

Leaving the incorrect IP address in place does not break any VCEM operations. The IP address is
only displayed to inform you that VCM is managed by VCEM from that IP address.

To correct the IP address in VCM, complete the following steps:

1.

Verify that the Windows host where VCEM is installed has its network adapters bound in the
correct order. The network adaptor handling communications with VCM should be first in the

120 Troubleshooting VCEM