Edit ports confirm window, Selected ports table – HP XP P9500 Storage User Manual
Page 401

Description
Item
Only 10 Gbps can be specified for the FCoE port. Auto cannot be specified
for the FCoE port.
Select the address of the selected port.
Address (Loop ID)
Select whether a fabric switch is set to ON or OFF. Only ON can be specified
for the FCoE port.
Fabric
Select the topology.
Connection Type
•
FC-AL: Fibre channel arbitrated loop
•
P-to-P (point-to-point). Only P-to-P can be specified for the FCoE port.
CAUTION:
Some fabric switches require that you specify point-to-point
topology. If you enable a fabric switch, check the documentation for the
fabric switch to determine whether your switch requires point-to-point
topology.
Edit Ports Confirm window
Confirm proposed settings, name the task, and then click Apply. The task will be added to the
execution queue.
Selected Ports table
Description
Item
The identifier of the port.
Port ID
The attribute of the port indicating I/O flow.
Attribute
•
Initiator: Issues I/O commands to a target port when I/O is executed
between storage systems with Continuous Access Synchronous, and so
on.
•
Target: Receives I/O commands from a host.
•
RCU Target: Receives I/O commands from an initiator when I/O is
executed between storage systems with Continuous Access Synchronous,
and so on.
•
External: Issues I/O commands to a target port of an external storage
system with External Storage.
Edit Ports wizard 401