Add lun paths confirm window, Added luns table – HP XP P9500 Storage User Manual
Page 380

Description
Item
The name of the port and the host group of assigned LUNs. This item
appears according to the number of assigned LUNs.
port ID
/ host group name
To change the LDEV name setting, select an LDEV and then click this button.
Change LDEV Settings
To change the LUN setting, select the check box in the table column of port
ID
/host group name, select the target LDEV, and then click this button.
Change LUN IDs
Add LUN Paths Confirm window
Confirm proposed settings, name the task, and then click Apply. The task will be added to the
execution queue.
Added LUNs table
Description
Item
The identifier of the LDEV.
LDEV ID
The name of the LDEV.
LDEV Name
The identifier of the parity group.
Parity Group ID
The pool names and pool identifiers.
Pool Name (ID)
If the LDEV is not used as a pool-VOL, a hyphen (-) appears.
The emulation types for each logical volume (or logical device). For LUSE
volumes, an asterisk (*) and a number appear on the right of the emulation
Emulation Type
type. For example, OPEN-9*3 indicates that three OPEN-9 volumes are
combined.
The size of each logical volume.
Capacity
The provisioning types for each logical volume.
Provisioning Type
•
Basic: Internal volume.
•
External: External volume.
•
THP: V-VOL of Thin Provisioning.
•
Snapshot: Fast Snap volume or Snapshot volume.
Displays the attribute of the LDEV.
Attribute
•
Command Device: Command device.
•
Remote Command Device: Remote command device.
380 LUN Manager GUI reference