HP Smart Update Manager User Manual
Page 84
Description
Parameter
YES
, NO
Enables you to override or downgrade an existing installation of
components in the selected bundle.
FORCEBUNDLE
Possible values:
YES
, NO
Downgrade to an earlier version of firmware for multi-node devices such
as hard drives and array controllers. (Applies to firmware only.)
DOWNGRADE
Possible values:
YES
, NO
Rewrite the same version of firmware only for multi-node devices such as
hard drives and array controllers. (Applies to firmware only.)
REWRITE
Possible values:
YES
, NO
Enables you to reboot, if required.
REBOOTALLOWED
Possible values:
YES
, NO
Create a message to be displayed prior to rebooting.
REBOOTMESSAGE
Possible values:
Any string (not exceeding 256 characters)
Delay before rebooting.
REBOOTDELAY
Possible values
Time in seconds
Limit the list of components to be updated.
COMPONENTSLIST
Possible values:
Component names with file extensions (.exe, .rpm, or .scexe)
Limit the list of bundle xml files to be filtered.
BUNDLESLIST
Possible values:
Bundle file names
This is a filter switch and enables you to install newer versions of
components defined in a PSP, ISP, or bundle.
ALLOWUPDATEBUNDLE
This parameter enables these components to replace the older versions of
the same component that might have shipped with the bundles.
Possible values:
YES
, NO
Defines the behavior when a remote node has an existing HP SUM session
in progress.
SKIPTARGET
Use this parameter to skip the host if an existing HP SUM session already
exists. A value of NO overrides the session in progress and reinitializes the
installation framework on the remote host.
NOTE:
If an HP SUM session discovers a remote node is running HP
SUM locally, HP SUM ignores the SKIPTARGET command and skips the
remote node.
Possible values:
YES
, NO
84
Using legacy scripts to deploy updates