Hot swap controller (hsc) – HP Integrity rx4610 Server User Manual
Page 73

Chapter 8: Server Management
66
•
Processor
presence
monitoring
•
Speaker ‘Beep’ capability on standby and when system is powered up
•
Itanium processor SEEPROM interface
•
Processor
temperature
monitoring
•
Hot plug PCI slot status monitoring
•
Processor bus speed setting
•
Chassis fan failure light control
•
Chassis power fault light control
•
Chassis power light control
•
SDR/SEL timestamp clock
•
Boardset FRU information interface
•
Fault Resilient Booting (FRB)
•
System management watchdog timer
•
Front panel diagnostic interrupt handling (also called the Init Switch)
•
Diagnostics interrupt (Init status monitor)
•
Event
receiver
•
System interface to the IPMB
•
Secure mode control, including video blank option monitoring and control and front panel
lock/unlock initiation.
•
IPMI Management Controller Initialization Agent
•
Magic Packet and Wake on LAN / Power on LAN support
•
Emergency Management Port (EMP) interface
Intelligent Chassis Management Bus (ICMB) Controller
The ICMB Controller resides on the Legacy I/O Board. It serves as a bridge between the
internal Intelligent Platform Management Bus (IPMB) and the external Intelligent Chassis
Management Bus (ICMB). The internal IPMB transports server management information
within a system, and the external ICMB transports server management information between
various chassis in a server(s) and peripherals cluster configuration.
Hot Swap Controller (HSC)
The Hot Swap Controller (HSC) resides on the Power Distribution Board (T-Docking). The primary
functions of the HSC are as follows:
•
Implements the SAF-TE command set
•
Controls the fault lights