Chapter 11: Troubleshooting

142

A second set of messages will be seen later in the POST, which indicates where the memory test
found errors. The sequence is as follows:

Error in memory subsystem: (Lower/Upper) Board, DIMM XX

ERRORS FOUND IN MEMORY SUBSYSTEM. FAILING ROWS WILL BE MAPPED OUT
ON THE NEXT RESET. IT IS STRONGLY SUGGESTED THAT YOU RESET THE
SYSTEM NOW.

ALLOWING THE SYSTEM TO CONTINUE TO BOOT MAY RESULT IN UNSTABLE
SYSTEM BEHAVIOR AND/OR HARD DISK CORRUPTION.

Hit to load defaults or to run SETUP or to continue

Examples

The following examples assume that the total memory installed is 32 GB (32768 MB).

Example #1

The system boots with 32 GB of memory installed and, no defects found, will report the following:

32768 MB Total Memory Installed
32768 MB Configured
32768 MB Tested

Example #2

Consider a system populated that has the entire upper board memory slots with 1 GB DIMMs. The
first row test and the base row test passed without errors. The extended memory test detected a
memory error in DIMM 17. The following messages will appear:

32768 MB Total Memory Installed
32768 MB Configured
32768 MB Tested
Memory Errors Detected