beautypg.com

HP Identity Driven Manager Software Series User Manual

Page 151

background image

4-11

Using the Secure Access Wizard

Using Secure Access Wizard

Figure 4-9. Secure Access Wizard, Advanced Settings for Wired 802.1X

c.

Click the check box to select the setting to configure, then enter the
parameter to be applied.

When a parameter is configured, the

Reset to default values

option is

enabled. Click the link to restore the advanced settings for wired
802.1X defaults.

Advanced 802.1X settings for wired devices include:

TX period

- The period of time the switch waits until retransmission of

EAPOL PDU (default 30 sec.). Valid values are 1-65353.

Logoff period

- The period of time (seconds) after which a client will

be considered removed from the port for a lack of activity. Disabled
by default, valid values are 0-999999999, 0 is disabled

Supplicant timeout

- The authentication server response timeout

(default 30 sec). Valid values are 1 - 300.

Server timeout

- The authentication server response timeout (default

30 sec). Valid values are 1-300.

Max requests

- The maximum number of times the switch retransmits

authentication requests. Valid values are 1-10, the default value is 2.