Statovnm – HP NonStop G-Series User Manual
Page 84
Appendix C: OVNM Utilities 84
STATOVNM
The STATOVNM TACL utility will show the status of the various OVNM components on the HP NonStop server.
To run the utility on the HP NonStop server, you need to switch to the volume.subvolume where OVNM is
installed. To use the utility, use the following command at the prompt:
Run STATOVNM
$DATA05 OVNM 14> run statovnm
--------------------------
OVNM STATUS UTILITY
--------------------------
Data extracted from configuration in $DATA05.OVNM.
Report generated: October 1, 2009 13:16:52
License Key XXXXXXXXXXXXXXXXXXXX
MaxClients 50
TCP IP process $ZTC0
TCP IP port 7370
MaxServiceProviders 64
Main Process Name $OVOCC $DATA05.OVNM.ACC
Distributor Process Name $OVDAL $SYSTEM.
SYS10.EMSDIST
Collector(s) $0
Filter(s) $DATA05.OVNM. PASSALL
Distributor Process Name $OVDA2 $SYSTEM.SYS10.EMSDIST
Collector(s) $ZLOG
Filter(s) $DATA05.OVNM.ZTSMFLTR
Elink Process Name $OVELK $DATA05.OVNM.ELINK
Master Monitor Process Name $OVMON $DATA05.OVNM.ORMMST
Server Monitor Process Name $OVM00 $DATA05.OVNM.ORMCOM
Server Monitor Process Name $OVM01 $DATA05.OVNM.ORMCOM
List Process Name $OVLST $DATA05.OVNM.LSTCOM
Tacl Gateway Process Name $OVGTA
MQ Series Process Name $OVMQL Not being used.
Event Correlation Process Name $OVECL $DATA05.OVNM.AOECL
------------------- S T A T U S -------------------------------
Your IP port (7370) in $ZTC0 appears to be fine. OK
OVNM Main process ($OVOCC) is up and running. OK
Distributor process ($OVDAL) is up and running. OK
Distributor process ($OVDA2) is up and running. OK
Elink process ($OVELK) is up and running. OK
OVNM Monitor process ($OVMON) is up and running. OK
Server Monitor ($OVM00) is up and running. OK
Server Monitor ($OVM01) is up and running. OK
OVNM Configuration process ($OVLST) is up and running. OK