STATOVNM

The STATOVNM TACL utility will show the status of the various OVNM components on the HP NonStop server.
To run the utility on the HP NonStop server, you need to switch to the volume.subvolume where OVNM is

installed. To use the utility, use the following command at the prompt:

Run STATOVNM

$DATA05 OVNM 14> run statovnm

--------------------------

OVNM STATUS UTILITY

--------------------------

Data extracted from configuration in $DATA05.OVNM.

Report generated: October 1, 2009 13:16:52

License Key XXXXXXXXXXXXXXXXXXXX

MaxClients 50

TCP IP process $ZTC0

TCP IP port 7370

MaxServiceProviders 64

Main Process Name $OVOCC $DATA05.OVNM.ACC

Distributor Process Name $OVDAL $SYSTEM.
SYS10.EMSDIST

Collector(s) $0

Filter(s) $DATA05.OVNM. PASSALL

Distributor Process Name $OVDA2 $SYSTEM.SYS10.EMSDIST

Collector(s) $ZLOG

Filter(s) $DATA05.OVNM.ZTSMFLTR

Elink Process Name $OVELK $DATA05.OVNM.ELINK

Master Monitor Process Name $OVMON $DATA05.OVNM.ORMMST

Server Monitor Process Name $OVM00 $DATA05.OVNM.ORMCOM

Server Monitor Process Name $OVM01 $DATA05.OVNM.ORMCOM

List Process Name $OVLST $DATA05.OVNM.LSTCOM

Tacl Gateway Process Name $OVGTA

MQ Series Process Name $OVMQL Not being used.

Event Correlation Process Name $OVECL $DATA05.OVNM.AOECL

------------------- S T A T U S -------------------------------

Your IP port (7370) in $ZTC0 appears to be fine. OK

OVNM Main process ($OVOCC) is up and running. OK

Distributor process ($OVDAL) is up and running. OK

Distributor process ($OVDA2) is up and running. OK

Elink process ($OVELK) is up and running. OK

OVNM Monitor process ($OVMON) is up and running. OK

Server Monitor ($OVM00) is up and running. OK

Server Monitor ($OVM01) is up and running. OK

OVNM Configuration process ($OVLST) is up and running. OK