HP NonStop G-Series User Manual
Page 69
Troubleshooting OVNM 69
Option 3: NOCATCHUP
OVNM provides the NOCATCHUP facility, which can be used in case the user is not willing to retrieve the events
logged during any kind of connection outage. In this case, no catch up request will be sent for the particular
node. Follow the steps below to configure the HP NonStop node in Nocatchup file.
1.
Access the Nocatchup file available at “C:\Program Files\HP OpenView\bin” location.
2.
Add the HP NonStop node name for which NOCATCHUP facility is to be activated using the following
syntax.
NODE \NODE1
NODE \NODE2
3.
Restart the Agents.
Option 4: OVNMMODE 48
This feature provides the facility to receive the events in the 4.8 version format. Follow the steps below to
configure the functionality.
1.
Access the ovnmconf.cfg file at “C:\Program Files\HP OpenView\bin” location.
2.
Add the following line in the ovnmconf.cfg file.
OVNMMODE48 ON/OFF
3.
Restart agents after editing the ovnmconf.cfg file.