beautypg.com

Appendix j: elink messages in hpom – HP NonStop G-Series User Manual

Page 115

background image

Appendix J: Elink Messages in HPOM 115

Appendix J: Elink Messages in HPOM

This section provides a list of common Elink messages along with explanations.

1.

Connection lost with remote Node
This alert is generated by OVNM_SPI process. This implies the connection is lost with the specified HP

NonStop node. It could be due to OVNM component on the NonStop is brought down or network outage

between the front-end OVNM system and NonStop system. If the connection is broken due to network

problem and none of the Primary/Backup OVNM is connected to the remote NonStop host; then EMON

will put distributors in IDLE state. As soon as Primary/Backup front-end OVNM re-establishes the

connection, EMON points the distributors back to the time when the connection was broken and processes

all the alerts lost during the network outage.

2.

Connection established with remote Node
This alert is generated by OVNM process and implies that the connection is established with the specified

HP NonStop node.

3.

Connection lost with local ELINK
This alert is generated by the OVNM_SPI process. This implies that the connection is lost to the local Elink

running on the front-end OVNM system. The reason for the message could be that the Elink is killed or

stopped by the user on the FE Windows/UNIX system. To recover from the problem, start the Elink process

on the front-end OVNM system (Windows/UNIX).

4.

Connection resumed with local ELINK
This alert is generated by the OVNM_SPI process. This implies that the connection is resumed with the local

Elink running on the front-end OVNM system.

5.

Elink is not responding
This alert is generated by the OVNM_SPI process. This implies that the OVNM_SPI process is unable to

communicate to the local Elink running on the front-end OVNM. The remedy for this error is to stop and

restart the local Elink on the front-end.

6.

TANDEM.ELINK.G06 100 ELINK:Primary/Backup Adapter Connection Lost
This alert is generated by NonStop Elink process. This implies that the Primary or Backup OVNM

connection is lost. This is an informational message and can be used to inform that the front-end OVNM

has problems (down or network outages). This alert can be automated in OCC and mail/page messages

can be generated.

7.

TANDEM.ELINK.G06 100 ELINK:Primary/Backup Adapter Connection Established
This alert is generated by NonStop Elink process. This implies that the Primary or Backup OVNM

connection is established. This is an informational message.

This manual is related to the following products: