HP StorageWorks MSL6000 Tape Library User Manual
Page 125
MSL6000 series tape library user guide 125
5014
Drive Already Loaded
(Cleaning operation failed because the
drive already has a cartridge inserted.)
•
Press the Enter button to clear the
message.
•
Invalid user initiated operation. Set
parameters correctly and try again.
•
If the tape in the drive is not in use,
unload the drive and retry the cleaning
operation.
5015
Expired Clean'g Cart
(Cleaning operation failed due to an
expired cleaning cartridge.)
•
Press the Enter button to clear the
message.
•
Remove expired cleaning cartridge from
library and discard. Replace with new
cleaning cartridge.
5016
Not a Clean'g Cart
(Cleaning operation failed because the
loaded cartridge is not a cleaning
cartridge.)
•
Press the Enter button to clear the
message.
•
Make sure tape in reserved slot is a
cleaning cartridge.
•
Invalid user initiated operation. Set
parameters correctly and try again.
5035
Drive Timeout Error
(Cleaning operation failed because the
drive timed out.)
•
Press the Enter button to clear the
message.
•
Invalid user initiated operation. Set
parameters correctly and try again.
•
Ensure the drive shows good status
through the drive status window.
503B
Move Command Fail
(A front panel move operation failed.)
•
Press the Enter button to clear the
message.
•
Invalid user initiated operation. Set
parameters correctly and try again.
503C Clean Operation Timeout
(Cleaning operation failed because the
drive timed out.)
•
Press the Enter button to clear the
message.
•
Invalid user initiated operation. Set
parameters correctly and try again.
•
Ensure the drive shows good status
through the drive status window.
Table 10
Fault Symptom Codes (continued)
FSC
Message
ERP