HP StorageWorks MSL6000 Tape Library User Manual
Page 115

MSL6000 series tape library user guide 115
3054
Need 1 Drive Minimum
(No available drive to run diag.)
•
Install or activate a drive.
•
Press the Enter button to clear the
message.
•
Invalid user initiated operation. Set
parameters correctly and try again.
3055
Memory Allocation Error
(Memory allocation error in diagnostic.)
•
Cycle power to the library or reboot by
using the LCD touch display. Wait 30
seconds to power up again.
3057
Invalid Magazine Type
(Unsupported magazine type detected.)
•
Upgrade firmware if a newer revision
exists.
•
Press the Enter button to clear the
message.
•
Check magazine type.
•
Invalid user initiated operation. Set
parameters correctly and try again.
3058
Magazine Type Change Not Handled
(Unsupported magazine type detected.)
•
Upgrade firmware if a newer revision
exists.
•
Press the Enter button to clear the
message.
•
Check drive type.
•
Invalid user initiated operation. Set
parameters correctly and try again.
3059
Drive Type Not Supported
(Unsupported magazine type detected.)
•
Upgrade firmware if a newer revision
exists.
•
Press the Enter button to clear the
message.
•
Invalid user initiated operation. Set
parameters correctly and try again.
3060
Zone Sequence Error
•
Cycle power to the library or reboot by
using the LCD touch display.
• Update the Map using the LCD touch
display. (Menu -> Maintenance -> Force
reconfiguration)
3061
Homing Error
(Unable to complete Shuttle Homing
Algorithm.)
•
Cycle power to the library or reboot by
using the LCD touch display.
• Update the Map using the LCD touch
display. (Menu -> Maintenance -> Force
reconfiguration)
Table 10
Fault Symptom Codes (continued)
FSC
Message
ERP