MSL6000 series tape library user guide 119
307A
Diag get drive 2 status failed
(Failed to get drive status, communication
error.)
•
Press the Enter button to reboot.
•
Ensure the drive shows good status
through the drive status window.
•
Deactivate the drive using the GUI control
panel maintenance menu.
•
Reseat drive.
•
Check cabling.
•
Load/unload a cartridge to the drive to
verify.
•
Check the tape cartridge used in the last
operation for damage.
•
Run the cartridge cycle diagnostic to
verify.
307B
Diag get drive 3 status failed
(Failed to get drive status, communication
error.)
•
Press the Enter button to reboot.
•
Ensure the drive shows good status
through the drive status window.
•
Deactivate the drive using the GUI control
panel maintenance menu.
•
Reseat drive.
•
Check cabling.
•
Load/unload a cartridge to the drive to
verify.
•
Check the tape cartridge used in the last
operation for damage.
•
Run the cartridge cycle diagnostic to
verify.
3082
Drive Stow Failed, Media Returned to
Source
•
Press the Enter button to clear the
message.
•
Use only media approved for the drive
type.
•
Invalid user initiated operation. Set
parameters correctly and try again.
3083
Drive Stow Failed, Media Remains in
Drive
•
Press the Enter button to clear the
message.
•
Invalid user initiated operation. Set
parameters correctly and try again.
•
Ensure cartridges are in magazines.
Table 10
Fault Symptom Codes (continued)
FSC
Message
ERP