HP StorageWorks MSL6000 Tape Library User Manual
Page 124
Troubleshooting
124
3300
Rotary Jammed
(Rotary track could not reach target
location.)
•
Press the Enter button to reboot.
•
Cycle power to the library or reboot
using the GUI touch screen.
•
Ensure that there are no obstructions
inside the library (all cartridges are in
magazines).
•
Ensure cartridges are fully inserted in the
magazine(s).
3301
Shuttle on Wrong Side Of The Rotary
(Zone indicators show that the shuttle is
backwards on the rotary track during
power-up initialization.)
•
Press the Enter button to reboot.
•
Cycle power to the library or reboot
using the GUI touch screen.
3303
Shuttle Not Attached to Cable
•
Cycle power to the library or reboot by
using the LCD touch display.
• Check cable connections.
3400
Pass-through Elevator Jammed
(Pass-through shuttle could not reach
target location.)
•
Press the Enter button to reboot.
•
Cycle power to the library or reboot
using the GUI touch screen.
•
Ensure that there are no obstructions
inside the library (all cartridges are in
magazines).
•
Check pass-through alignment.
3500
Vertical Elevator Jammed
(Vertical elevator could not reach target
location. 10U libraries only).
•
Press the Enter button to reboot.
•
Cycle power to the library or reboot
using the GUI touch screen.
•
Ensure that there are no obstructions
inside the library (all cartridges are in
magazines).
5011
All Slots Empty
(There are no cartridges installed in any
of the reserved cleaning slots.)
•
Press the Enter button to clear the
message.
•
Insert cleaning cartridge in reserved
cleaning slot.
•
Invalid user initiated operation. Set
parameters correctly and try again.
Table 10
Fault Symptom Codes (continued)
FSC
Message
ERP