HP StorageWorks MSL6000 Tape Library User Manual
Page 104
Troubleshooting
104
0B02
Public Ethernet Set IP Error
(The library could not set the IP
parameters)
•
Make sure a valid Ethernet address has
been programmed using the LCD touch
display. (Menu -> Maintenance ->
Library)
• Reboot the library
1001
SCSI Firmware Error
(Internal SCSI task processing error.
Unexpected state or hardware status.)
•
Turn off power to the library and inspect
connectors and cables.
•
Check the SCSI cable connections to
make sure they are secured.
•
Make sure the library controller board
has SCSI termination.
1002
SCSI FIFO Empty
(The SCSI controller data FIFO is empty
but should contain more data bytes.)
•
Turn off power to the library and inspect
connectors and cables.
•
Check the SCSI cable connections to
make sure they are secured.
•
Make sure the library controller board
has SCSI termination.
1003
SCSI FIFO Error
(The SCSI controller data FIFO should be
empty but still contains data bytes.)
•
Turn off power to the library and inspect
connectors and cables.
•
Check the SCSI cable connections to
make sure they are secured.
•
Make sure the library controller board
has SCSI termination.
1004
SCSI Gross Error
(The SCSI controller detected a gross error
condition. Invalid SCSI bus phase or
DMA error.)
•
Turn off power to the library and inspect
connectors and cables.
•
Ensure SCSI options are set correctly.
•
Check the SCSI cable connections to
make sure they are secured.
•
Make sure the library controller board
has SCSI termination.
•
Check host SCSI cable and connections.
Table 10
Fault Symptom Codes (continued)
FSC
Message
ERP