HP StorageWorks MSL6000 Tape Library User Manual
Page 111
MSL6000 series tape library user guide 111
3016
Drive Status Failure
•
Press the Enter button to reboot.
•
Ensure the drive shows good status
through the drive status window.
•
Deactivate the drive using the GUI control
panel maintenance menu.
•
Reseat the drive.
•
Check cabling.
•
Load/unload a cartridge to the drive to
verify.
•
Check the tape cartridge used in the last
operation for damage.
•
Run the cartridge cycle diagnostic to
verify.
3017
Drive In Flux Timeout
(Time-out waiting for drive to clear the full
status.)
•
Press the Enter button to reboot.
•
Ensure the drive shows good status
through the drive status window.
•
Deactivate the drive using the GUI control
panel maintenance menu.
•
Reseat the drive.
•
Check cabling.
•
Load/unload a cartridge to the drive to
verify.
•
Run the cartridge cycle diagnostic to
verify.
3018
Drive Load Retry Failed
(SLTO drive fail to load, detected in drive
task.)
•
Press the Enter button to reboot.
•
Ensure the drive shows good status
through the drive status window.
•
Deactivate the drive using the GUI control
panel maintenance menu.
•
Reseat the drive.
•
Check cabling.
•
Load/unload a cartridge to the drive to
verify.
•
Check the tape cartridge used int he last
operation for damage.
•
Run the cartridge cycle diagnostic to
verify.
Table 10
Fault Symptom Codes (continued)
FSC
Message
ERP