Uint32 getsupportedsizerange, Method overview, Method parameters – HP SAN Virtualization Services Platform User Manual
Page 71: Uint32 getavailableextents
uint32 GetSupportedSizeRange
Method Overview
Returns the usable size range for creating virtual disks from this pool. If the method is successful, return
0 (Method Completed OK).
Method parameters
IN/OUT
Comments
Type
Parameter Name
IN-Required
Only 3 "StorageVirtualDisk" is accep-
ted, all other values are rejected.
uint16
ElementType
IN
Accept this value only if it is NULL,
or if the passed in StorageSetting
reference represents any setting in-
stance of SNIA_StorageSetting, as
long as the following criteria is met:
•
DataRedundancy = 1
•
PackageRedundancy = 0
•
ExtentStripeLengthMin = 1
•
UserDataStripeDepthMin = 1
SNIA_StorageSetting REF
Goal
OUT
System Minimum Volume Size
uint64
MinimumVolumeSize
OUT
Set this value to the same value as
RemainingManagedSpace.
uint64
MaximumVolumeSize
OUT
Should be Set to 1 MB (1048576
bytes).
uint64
VolumeSizeDivisor
uint32 GetAvailableExtents
Method Overview
Ignore the parameters. Always return 1 "Not supported".
Method parameters
IN/OUT
Comments
Type
Parameter Name
N/A
N/A
N/A
N/A
SAN Virtualization Services Platform SMI-S User Guide
71
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)