Uint32 getsupportedstripelengthrange, Method parameters, Getsupportedstripedepths – HP SAN Virtualization Services Platform User Manual
Page 62: Method overview
IN/OUT
Comments
Type
Parameter
Name
OUT
The output value is an array populated with an integer count for each
possible stripe length in the array.
NOTE:
The system will use a heuristic to return only stripe lengths of
possible "Right-Sized" stripes. For example: Suppose there are 5
available primordi¬al extents (HPSVSP_ImportedExtent), 3 extents
of 50GB and 2 extents of 100GB. Although there are 5
backend-LU's available, the stripe sizes returned will be [1,2,3],
since the largest stripe length possible (without using dissimlar
sized extents) would consist of the 3 50GB extents.
uint16
StripeLengths
uint32 GetSupportedStripeLengthRange
Method parameters
This method returns the possible stripe lengths. All parameters are ignored. This method always returns:
3 "Use GetSupportedStripeLengths instead".
IN/OUT
Comments
Type
Parameter Name
OUT
N/A
uint16
MinimumStripeLength
OUT
N/A
uint16
MaximumStripeLength
OUT
N/A
uint16
StripeLengthDivisor
GetSupportedStripeDepths
Method Overview
This method returns the 'stripe sizes' allowed.
IN/OUT
Comments
Type
Parameter Name
OUT
uint64
StripeDepths
Block Services Package
62
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)