beautypg.com

Dwyer DLI User Manual

Page 96

background image

96 |

P a g e

5.

Staggering of scheduled transmissions – By starting the RF transmitters at different times, the

transmissions will not overlap until the time drift between the transmitter clocks causes transmission

collisions. At room temperature, the typical clock will drift no more than 1-2 seconds per day. Higher

or lower temperatures will cause more drift. For example: if you use delay start to start one

transmitter at 11:00:00 and a second transmitter at 11:00:30 (at 1 minute sample rates), then typically

they would run for about 30 days (at similar temperatures) before there was a possibility of a

collision. However, temperature fluctuations that deviate up or down from room temperature will

generally cause the clock to run slower. Thus, potential collisions depend the time between samples,

relative clock accuracy and relative ambient temperatures.

6.

Prime number scheduled transmissions – This method utilizes prime numbers to help prevent

transmission collisions. See the next section for further detail on this method.

Wireless: Autosave of Wireless Data

A convenient feature of the Wireless Real Time Chart Recording mode of the Dwyer software is the

ability to automatically save the data to all supported data file formats such as (.CSV files); software

version 2.00.70 or higher is required. Data can also be saved manually using "File/Save As" in the

software or the "Save As" button in the "Configure Wireless Data" dialog. Note. While the Auto

Save feature is enabled, system memory consumption will go up. To avoid excessive PC memory

consumption, Dwyer recommends setting the amount of readings that are saved to the highest value

(e.g. every 1000 Readings) that is possible. For operations with 1-2 data loggers, it is OK to set

“200” as the reading count. To select where a file is automatically saved/archived to, simply click the

“Browse” button and specify a directory where the files will be automatically saved. Note. Initially,

the default directory is the same as that set in your software preferences under the “Data” tab. To

setup the autosave feature, ensure your wireless data logger has been started by using a standard

interface cable, and that the RFC101A wireless receiver is now attached to the target PC. Precisely,

follow the steps:

1. Start the logger as in the section

Starting the Device and Synchronizing the Transmitter

2. Under the

Communications menu, ensure that Accept Real Time Wireless Input is checked.

3. Choose the

Composite Graph tab to view all of the wireless data set.

4. Click

Device Menu and note the following menu additions/changes pertaining to wireless

transmissions:

Configure Wireless Data

Wireless Statistics

Wireless Alarm Setup

5. Click

Device menu then Configure Wireless Data. The Configure Wireless Data window below

will appear and list the loggers whose wireless data have been received.

This manual is related to the following products: