Badger Meter Vortex Meters User Manual
Page 8

Page 6
•
Save/Restore Configuration - This menu allows the user to save and recall setting from
non-volatile memory (EEPROM).
Racine Federated HART Interface Utility
FL_METER
0
4
0
72
0
RWG15
Tag:
PV (Volume)
Model Number:
Analog Output Current:
Percent of Range:
Process Temperature:
Process Pressure:
ft3/min
mA
%
degF
psi
Connect
Connect
Update
Begin Continuous Display Update
Continuous Screen Update:
Meter In-Service:
Edit Mode:
Fixed Current Value:
Configuration Changed, Not Saved:
Password Protection:
Tools
About
Com Port
Save/Restore Configuration
Edit/In-Service
Configure Meter
Save/Restore Configuration
Save Configuration
Restore Factory Configuration
Restore Configuration
(See the
Save/Restore Configuration Section for more information.)
•
Com port - This selection opens a dialog box that allows the user to select the serial port.
Com Port
Close
Update
Com Port
You must exit and restart
the program for Com Port
changes to take effect.
1
- BEACON Advanced Metering Analytics (AMA) (2 pages)
- GALAXY (16 pages)
- GALAXY (20 pages)
- GALAXY (28 pages)
- ORION Cellular Endpoint (2 pages)
- ORION Cellular Endpoint (32 pages)
- ORION Cellular Endpoint (80 pages)
- ORION Migratable (ME) (96 pages)
- ORION Migratable (ME) (72 pages)
- ORION Migratable (ME) (60 pages)
- ORION Classic (CE) (2 pages)
- ORION Classic (CE) (20 pages)
- ORION Classic (CE) (2 pages)
- ORION Classic (CE) (28 pages)
- ORION Classic (CE) (8 pages)
- ORION Classic (CE) (16 pages)
- ORION Classic (CE) (32 pages)
- ORION Classic (CE) (20 pages)
- ORION Classic (CE) (28 pages)
- ORION Fixed Network (SE) (4 pages)
- ORION Fixed Network (SE) (48 pages)
- ORION Migratable (ME) (48 pages)
- ORION Migratable (ME) (2 pages)
- ORION Migratable (ME) (32 pages)
- ORION Migratable (ME) (20 pages)
- E-Series Ultrasonic Meters (2 pages)
- E-Series Ultrasonic Meters (12 pages)
- M-Series M2000 (24 pages)
- M-Series M2000 (2 pages)
- M-Series M2000 (4 pages)
- M-Series M2000 (60 pages)
- M-Series M3000 (40 pages)
- M-Series M4000 (36 pages)
- M-Series M5000 (36 pages)
- M-Series M5000 (4 pages)
- M-Series Field Verification Device (24 pages)
- Recordall Disc Series Meters (4 pages)
- Recordall Turbo Series Meters (20 pages)
- Recordall Transmitter Register (RTR) (2 pages)
- Industrial Turbo (16 pages)
- Water Conditioning (16 pages)
- Recordall Compound Series Meters (2 pages)
- Recordall Compound Series Meters (20 pages)
- Recordall Compound Series Meters (16 pages)
- Remote Electronic Display (RED) (8 pages)