Configuration report – Badger Meter Vortex Meters User Manual
Page 40

Configuration Report
The configuration report is a convenient tool to display all the customer configurable settings of
the meter. The report generated by this dialog box is useful for record keeping and for servicing
the meter. A Racine customer service technician can refer to the information provided by this
dialog box to troubleshoot the meter. The “Read” button will refresh the screen with new data
from the meter. Several seconds are required to refresh the screen because of the extensive
information read from the meter. The “Print” button will allow the user to print the information to
a file or to a printer. After clicking the “Print” button, a “Print Option” dialog box will ask the user
“Do you want to print to a file?” If “Yes” is selected, the “Save as type” dialog box will appear
and the user can select where the file will be saved. If “No” is selected, the “Print” box will ap-
pear and the user can select a printer. The print function is handy for faxing the configuration
information to Racine for technical assistance. All fields in this dialog box are read only.
Read
Close
Configuration Report
Model Number
Primary Variable:
Device ID:
Loop Current
Process Temp:
User Spec TemP:
User Spec Pressure:
Process Density:
Process Viscosity:
Input Current:
Process Pressure
User Spec Density:
User Spec Visc:
Damping Value:
Pipe ID:
Standard Temp:
Atmospheric Pres:
Low Flow Cutoff:
Pulse Output Mode:
Upper Rng Freq:
Totalizer Value:
Totalizer Mode:
Totalizer Multiplier:
162
RNG
0
4
74
0
4.04381
0.018221
74
0
0.073755
0.0185
6
0.07528
2
60
14.57
25
Disabled
5000
0.e0
Stopped
0.001
f/min
mA
F
mA
cP
cP
PSI
lb/cft
lb/cft
Inches
PSI
Seconds
F
Hz
Hz
DegF
psi
Ver:
to
to
PSI
Hz
lb/cft
PSI
Hz
Hz
PSI
Part Number:
PV Type:
Tag:
Analog Output Rng:
Temp Source:
Shedding Freq:
Input Range:
Dens & Visc Src:
Table:
Input Pressure:
Pressure Source:
Standard Density:
LCD Setting:
Alarm Current:
Standard Pressure:
K Factor:
Pulse Output Freq:
User Spec Freq:
Roll Over Value:
Cstm Totalizer Unit:
FL_METER
RFNG12-150SNNS
Velocity
0
10200
User Specified
User Specified
0.41069
AIR
2
0
0
150
Property Table
Low (3.75 mA)
0.076415
Primary Variable
14.696
1
0
1000
1000000
Page 38