Process temperature – Badger Meter Vortex Meters User Manual
Page 20

Page 18
process Temperature
The Process Temperature settings are accessed through the “Process Temperature” dialog
box. To bring up this box, click the “Configure Meter” pull-down menu on the Main screen and
then select “Process Temperature”.
Process Temperature
Process Temperature Units:
Process Temperature Source:
Process Temperature:
Integrated RTD
°F
User Defined
User Defined Temperature
Steam Table
Steam Table
Close
Write
Read
60
degF
72
The primary purpose of this dialog box is to tell the meter where it can get process temperature
information. The meter must know the process temperature in order to temperature compen-
sate the flow measurements. The meter also needs to know the process temperature in order
to make standard flow measurements. The units that may be selected are:
• degF (Degrees Fahrenheit)
• degC (Degrees Centigrade)
• degR (Degrees Rankine)
• Kelvin (Degrees Kelvin)
The data displayed by this window is read from the meter when the window is opened and
when the user clicks the Read or Write buttons.
process Temperature source - There are three different sources that can be selected for the
Process Temperature:
• An integrated RTD
• A user defined temperature value
• A steam table
NOTE: The integrated RTD selection is not available on “non-compensating” models.