Calibration – Badger Meter Vortex Meters User Manual
Page 41

Calibration
The calibration selection is only necessary when the meter needs to be serviced. The Racine
customer service technician will utilize or direct the customer to the use of these settings.
Racine Federated HART Interface Utility
FL_METER
0
4
0
72
0
RWG15
Tag:
PV (Volume)
Model Number:
Analog Output Current:
Percent of Range:
Process Temperature:
Process Pressure:
ft3/min
mA
%
degF
psi
Connect
Connect
Update
Begin Continuous Display Update
Continuous Screen Update:
Meter In-Service:
Edit Mode:
Fixed Current Value:
Configuration Changed, Not Saved:
Password Protection:
Tools
About
Com Port
Save/Restore Configuration
Edit/In-Service
Configure Meter Tools
Totalizer
Property Tables
Fixed Analog Output
Diagnostics
Configuration Rpt
Calibration
►
Flow Data
Digital Pots
The “Flow Data” selection will provide the technician with fields of continuous data.
Close
Flow Data
Reynolds:
0
Strouhal:
0.1962
Frequency:
0
Missing Pulses:
0
FV (Velocity):
0
Page 39
- BEACON Advanced Metering Analytics (AMA) (2 pages)
- GALAXY (16 pages)
- GALAXY (20 pages)
- GALAXY (28 pages)
- ORION Cellular Endpoint (2 pages)
- ORION Cellular Endpoint (32 pages)
- ORION Cellular Endpoint (80 pages)
- ORION Migratable (ME) (96 pages)
- ORION Migratable (ME) (72 pages)
- ORION Migratable (ME) (60 pages)
- ORION Classic (CE) (2 pages)
- ORION Classic (CE) (20 pages)
- ORION Classic (CE) (2 pages)
- ORION Classic (CE) (28 pages)
- ORION Classic (CE) (8 pages)
- ORION Classic (CE) (16 pages)
- ORION Classic (CE) (32 pages)
- ORION Classic (CE) (20 pages)
- ORION Classic (CE) (28 pages)
- ORION Fixed Network (SE) (4 pages)
- ORION Fixed Network (SE) (48 pages)
- ORION Migratable (ME) (48 pages)
- ORION Migratable (ME) (2 pages)
- ORION Migratable (ME) (32 pages)
- ORION Migratable (ME) (20 pages)
- E-Series Ultrasonic Meters (2 pages)
- E-Series Ultrasonic Meters (12 pages)
- M-Series M2000 (24 pages)
- M-Series M2000 (2 pages)
- M-Series M2000 (4 pages)
- M-Series M2000 (60 pages)
- M-Series M3000 (40 pages)
- M-Series M4000 (36 pages)
- M-Series M5000 (36 pages)
- M-Series M5000 (4 pages)
- M-Series Field Verification Device (24 pages)
- Recordall Disc Series Meters (4 pages)
- Recordall Turbo Series Meters (20 pages)
- Recordall Transmitter Register (RTR) (2 pages)
- Industrial Turbo (16 pages)
- Water Conditioning (16 pages)
- Recordall Compound Series Meters (2 pages)
- Recordall Compound Series Meters (20 pages)
- Recordall Compound Series Meters (16 pages)
- Remote Electronic Display (RED) (8 pages)