Precision air conditioning smartcool™ 6 - 200kw, Technical data sd clcl units, Te ch nic al cl cl sd – Airedale SmartCool 11-233kW User Manual
Page 177: Performance data sd clcl

Technical Data SD CLCL Units
Performance Data SD CLCL
Chilled water inlet and outlet temperatures
Air On
15 / 20 °C
17 / 22 °C
18 / 24°C
20 / 26 °C
Temp. (°C)
TC
SC
TC
SC
TC
SC
TC
SC
/ %RH
(kW)
(kW)
(kW)
(kW)
(kW)
(kW)
(kW)
(kW)
33 / 26
84.5
84.5
73.6
73.6
64.8
64.8
53.5
53.5
SD18D090-CLCL-0
35 / 24
94.7
94.7
83.9
83.9
75.5
75.5
64.4
64.4
37 / 22
104.9
104.9
94.3
94.3
86.1
86.1
75.2
75.2
33 / 26
107.9
107.9
94.2
94.2
83.7
83.7
69.6
69.6
SD22D120-CLCL-0
35 / 24
120.4
120.4
107.1
107.1
96.9
96.9
83.2
83.2
37 / 22
133.2
133.2
119.9
119.9
110.1
110.1
96.5
96.5
33 / 26
131.9
131.9
115.0
115.0
101.2
101.2
83.6
83.6
SD25D140-CLCL-0
35 / 24
147.8
147.8
131.0
131.0
117.9
117.9
100.7
100.7
37 / 22
163.8
163.8
147.2
147.2
134.4
134.4
117.5
117.5
33 / 26
177.2
177.2
154.7
154.7
137.4
137.4
114.1
114.1
SD31D190-CLCL-0
35 / 24
197.9
197.9
175.8
175.8
159.1
159.1
136.5
136.5
37 / 22
218.9
218.9
197.0
197.0
180.7
180.7
158.5
158.5
33 / 26
206.5
206.5
180.4
180.4
160.7
160.7
133.9
133.9
SD35D225-CLCL-0
35 / 24
230.4
230.4
204.9
204.9
185.8
185.8
159.7
159.7
37 / 22
254.6
254.6
229.3
229.3
210.9
210.9
185.0
185.0
Precision Air Conditioning
SmartCool™ 6 - 200kW
177
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014
Te
ch
nic
al
CL
CL
SD