Unit SI:

Ton

Value:

Calculated

Weight Vac

Weight in vacuum: Sum of liquid and vapor mass.
Code:

None

Unit SI:

Ton

Value:

Calculated


Under Density:

Vct @ temp

Volume correction: Volume correction (reduction) factor - Table 53/54.
Code:

None

Unit SI:

Ton

Value:

Calculated


E. Ground insulation monitor for Radar power.


The radar power system is equipped with a ground insulation monitor.
Should a ground insulation error appear on the radar equipment, this will be
indicated by a buzzer and an alarm LED. The buzzer is silenced by pressing
the red button marked with silence. Please note that the alarm LED will still
indicate an alarm condition until the cause of the ground insulation error is
found and eliminated.

To locate the fault disconnect one of the radars at a time inside the radar
cabinet until the alarm LED turns of.
Please note that when the faulty radar/cable is located this radar should not
be connected again until the cause of the insulation fault is located and
eliminated.