beautypg.com

KROHNE CARGOMASTER User Manual

Page 30

background image

CARGOMASTER®5

Operators Manual - 30

Handle Alarms

Acknowledge - Silence

When the first alarm occurs, the alarm window turns from green to red. A
blinking text line will appear, stating what kind of alarm, and where it has
occurred. The window will stay red as long as there is an alarm situation. The
tank name will also appear with a red background in ValueTable

Silence

:

(F11) Will only stop the audible alarm. Has no effect
on what is shown in the alarm window

Alarm

Ack

.:

(Shift+F11) Will stop both the audible alarm and stop
the blinking in the alarm window. If more than one
alarm has occurred at the same time, this action will
also bring the next unacknowledged alarm to the top of
the list.

Overview

(Alt+F11) Shows a list of the current alarms along with some description on
the alarm given.

Screenshot 17Alarms list in Alarm Overview

The

TAG

identifies the location of the alarm,

CODE

names the cause of the

alarm.

Limit/Type

shows the active limit for the alarm and

Alarm Time

and

Reset

shows when the alarm occurred and eventually when it was reset.