CARGOMASTER®5
Operators Manual - 32
For tank groups:
From ValueTable (Alt+F3) select the Alarm layer tab. Enter a new value in the
Sum cell for the appropriate column. Or:
From Loading (F2) in the Group menu, select the Alarm tab and enter new
value to adjust. Clicking the More Alarms button will bring up more detailed
alarms.
From Seagoing (Alt+F2) or Discharge (Shift+F2) in the Group menu enter
new value to adjust
Note: Altering an alarm limit will not set the alarm to on or off status
Alarms on - off
Depending on alarm types, there are several ways to turn alarms on or off, or
adjust the limits:
For single tanks:
Click the tank in Tank Plan (Shift-F3); select the Alarm tab and
check/uncheck the alarm.
Or:
From ValueTable (Alt-F3) select the Alarm On/Off layer tab. Type on or off
in the appropriate cell.
For tank groups:
From ValueTable (Alt-F3) select the Alarm On/Off layer tab. Type on or off
in the Sum field for the appropriate column.
Or:
From Loading (F2), select the Alarms tab. Check / uncheck alarms to turn on
or off. The More Alarms button will display more detailed alarms.
From Seagoing (Alt-F2) or Discharge (Shift-F2) in the Group menu check or
uncheck the alarms to turn on or off
Available Alarm Types
The following alarms can be set:
Alarm code
Alarm name
Default limit
HHL
High High Level
98%
HIL High
Level 95%
LOL Low
Level 5%
LLL
Low Low Level
3%
HIT
High Temperature
50 deg Celcius
LOT
Low Temperature
0 deg Celcius