beautypg.com

KROHNE CARGOMASTER User Manual

Page 66

background image

CARGOMASTER®5

Operators Manual - 66

Restore User Data Only

This option restores your Group and Condition setup, including the current
zero-adjustment values. This option differs from the Restore All option in not
including the configurations of tanks, sensors and so on.

Replace sensor

In CARGOMASTER

© version 1.06b and later, sensor data can be replaced

from within the MMI program. In versions prior to 1.06b this task can only be
performed in the configuration program. (Program versions can be verified
from menu

System - Program version and status)

Before replacing sensor data, make sure you have a backup of your current
configuration, see the

Backup-Restore

chapter.

Replacement procedure

You need:

• Sensor data file for the new sensor, either already present in the

database directory on the harddrive, or on a floppy.

• A valid backup of your existing configuration.

1. Select the tank in which the sensor is to be replaced; either in the

Tankplan or the Valuetable view.

2. Right-click the tank and select “Tank Info”, and then select the

“Service” –tab. That should give you the following window:

Replace Sensor screenshot# 1: Tank Information- service tab