beautypg.com

Reference – KROHNE CARGOMASTER User Manual

Page 22

background image

CARGOMASTER®5

Operators Manual - 22

4. Reference

Groups

CARGOMASTER® sees any tank to be of a certain type. The native types are
Cargo, Ballast, Fuel/Lubrication, Temperature, Solids or Misc types. Tanks of
the same type can be grouped together. (Scratch Groups can be used to group
tanks of different types)

Groups are usually set up from the Loading menus (F2), but single tanks can
be added or removed from a group within the ValueTable also.

By organising tanks into groups one achieves common handling of densities,
alarm limits, grade sums and averages and sorted survey reports.

Group modes

Groups may be set in different modes. Each mode has a specific set of alarms
and limits.

Loading

:

A new group is automatically set in loading mode.
Loading mode enables typical alarm settings and levels
that apply for a loading situation. Suggested alarms are
HH Level, H Level, H Inert and Density Difference.

Discharge

:

Suggested alarms enabled for this mode are LoLo
Vol%, Lo Vol% and LO Inert.

Seagoing

:

Suggested alarms are Volume change (See note), high
and low temperatures and high and low inert pressures.

Set group to loading

Press

F2

or select menu GroupLoading. Select the group you want to set to

Loading and click OK.

Set group to Discharge

Press

Shift

+

F2

or select menu GroupDischarge. Select group and click OK.